Skip to content
Industrial WordPress theme for modern manufacturing websites

CT-C Hot Air Circulation Oven for Pharmaceutical and Herbal Processing: Aqueous Pharmaceutical Granules

CT-C Hot Air Circulation Oven is evaluated for aqueous pharmaceutical granules in pharmaceutical and herbal processing. The defined feed is aqueous-binder wet granules from the specified formulation. Match this duty to the material checks below and the unchanged original equipment parameters.

Material requirements · Equipment parameters · Inquiry

Aqueous Pharmaceutical Granules: Application and Process Requirements

For aqueous pharmaceutical granules, verify batch and tray uniformity; do not assume solvent-rated or sterile service. Begin with aqueous-binder wet granules from the specified formulation and confirm how the incoming grade varies before defining the drying cycle.

Feed, Product Quality and Downstream Handling

Review itemAqueous Pharmaceutical Granules
Defined feedaqueous-binder wet granules from the specified formulation
Material-specific focusverify batch and tray uniformity; do not assume solvent-rated or sterile service
Product checksloss on drying, assay uniformity, granule size and downstream tablet performance
Downstream handlingcontained cooling and transfer to the validated dosage-form process

Material Movement and Drying Control

Include loss on drying, assay uniformity, granule size and downstream tablet performance in the trial record. Fix the sampling locations and analytical methods before comparing trials; feed preparation and cooling can affect the measured result.

Drying Endpoint and Product Acceptance

After acceptance, arrange contained cooling and transfer to the validated dosage-form process. Review discharge, temporary holding and packaging exposure as part of the moisture-control plan.

Application-Specific Equipment Selection

CT-C Hot Air Circulation Oven selection for aqueous pharmaceutical granules starts with Hot Air Circulation Oven requirements and the defined feed. Assess hot air ovens and hot-air circulation drying together with tray drying; the batch oven drying duty must be demonstrated using representative material and the required finished-product specification.

Define contact materials, cleaning, containment and qualification for the actual formulation. This application description does not establish sterile service, solvent-rated construction or a validated pharmaceutical process.

View the CT-C Hot Air Circulation Oven range and original equipment specifications

Technical References for This Application

Document the material-specific process and its acceptance criteria. FDA process-validation guidance.

Review the manufacturing controls applicable to the intended pharmaceutical use. FDA Q7 manufacturing guidance.

Define equipment suitability, cleaning and qualification requirements. FDA pharmaceutical equipment considerations.

Review the dust characteristics of the collected dry material. HSE combustible-dust guidance.

Review the thermal duty and utilities for the actual feed. U.S. DOE process-heat reference.

Equipment Reference Parameters

These are the CT-C Hot Air Circulation Oven model specifications. The operating duty for aqueous pharmaceutical granules must be established from the feed and the finished-product requirements above.

ModelEquivalent ModelDrying Capacity (kg/batch)Fan Power (kW)Air Volume (m³/h)Heat-Transfer Area (m²)Steam Consumption (kg/h)Electric Heating (kW)Overall Dimensions (mm)TrolleysTraysWeight (kg)
CT-C-ORXH5-C300.5534505861300×1200×1600016680
CT-C-IARXH-7-C500.553450101091400×1200×2000124800
CT-C-IRXH-14-C100–1200.55×269002018152300×1200×20002481300
CT-C-I(B)RXH-14-C100–1200.55×269002018151400×2200×20002481300
CT-C-IIRXH-27-C200–2400.55×269004036302300×2200×20004961800
CT-C-IIIRXH-41-C300–3600.55×3103508072453300×2200×200061442300
CT-C-III(B)RXH-41-C300–3600.55×3103508072452300×3200×200061442300
CT-C-IVRXH-54-C400–4800.55×41380010090604450×2200×200081922800
CT-C-IV(B)RXH-54-C400–4800.55×41380010090602300×4200×200081922800
CT-C-VI/600–7200.55×620700160144904450×3200×2000122883800
ParameterProject Information
ProductMaterial form, initial moisture and temperature limits
BatchLoading quantity and production schedule
TraysTray quantity, dimensions and loading depth
HeatingAvailable heat source and temperature requirements
AirflowCirculation, ventilation and exhaust requirements
ControlsTemperature settings, timing and monitoring needs
InstallationAvailable utilities, space and cleaning requirements
Test ItemRecord or Assessment
LoadingMaterial, batch mass and tray distribution
PreparationBatch loading and initial moisture
HeatingAir and product temperatures and duration
Drying completionFinal moisture and drying time
Final productResidual moisture, appearance and product-specific checks
UtilitiesMeasured consumption under the stated test conditions

Discuss Aqueous Pharmaceutical Granules Drying

Send QUANPIN the incoming aqueous pharmaceutical granules specification, sample information and the required final product condition for an equipment review.

Start Optimizing Your
Drying Process Today.

Our engineers are ready to assess your material and recommend a reliable, cost-effective drying solution.

Chat on WhatsApp