Skip to content
Industrial WordPress theme for modern manufacturing websites

FZG Vacuum Tray Dryer for Pharmaceutical Manufacturing: Caffeine Crystals

FZG Vacuum Tray Dryer for Pharmaceutical Manufacturing: Caffeine Crystals

FZG Vacuum Tray Dryer is evaluated for caffeine crystals in pharmaceutical manufacturing. The defined feed is isolated caffeine crystals. Review the material-specific operating requirements below alongside the original equipment specifications.

Material requirements · Equipment parameters · Inquiry

Caffeine Crystals: Application and Process Requirements

For caffeine crystals, control residual process solvent and preserve the specified crystal and impurity profile. Start with isolated caffeine crystals, and identify the volatile phase and incoming variability before choosing a cycle.

Feed, Quality and Downstream Interface

Review itemCaffeine Crystals
Defined feedisolated caffeine crystals
Material-specific focuscontrol residual process solvent and preserve the specified crystal and impurity profile
Product quality checksmoisture, residual solvent, assay and particle distribution
Downstream handlingcontained qualified storage before formulation

Loading and Material Movement

Set layer depth, loading distribution and tray position; inspect the slowest drying locations.

Include moisture, residual solvent, assay and particle distribution in the trial record. Define the sampling locations and analytical methods before the test; a result from a different grade, loading pattern or residual liquor cannot establish the operating endpoint for this feed.

Material-Specific Configuration

Vacuum Tray Dryer selection for this feed should be assessed alongside the industrial vacuum dryer process description. Evaluate low-temperature vacuum drying and heat-sensitive material drying with representative caffeine crystals. This pharmaceutical vacuum drying application requires a material-specific sampling and acceptance plan.

After the batch meets the agreed specification, arrange contained qualified storage before formulation. Examine the effect of discharge, temporary holding and packaging exposure on the measured product condition. Establish the usable batch and cycle for this material; the original model parameters below remain the equipment reference, not a throughput promise for every formulation.

View the FZG Vacuum Tray Dryer range and original equipment specifications

Technical References for This Application

Agree material-specific sampling and acceptance criteria for the process. FDA process-validation guidance.

Review the quality and documentation requirements appropriate to the pharmaceutical duty. FDA Q7A manufacturing guidance.

Define product-contact surfaces, cleaning access and changeover requirements. FDA equipment and cleaning guidance.

Apply the relevant residual-solvent specification to the actual formulation; this is separate from water content. FDA ICH Q3C residual-solvent guidance.

Use the actual powder test data when defining dust collection and handling. HSE combustible-dust handling guidance.

Equipment Reference Parameters

These are the FZG Vacuum Tray Dryer model specifications. The operating duty for caffeine crystals must be established from the feed and the finished-product requirements above.

ItemYZG-600YZG-1000YZG-1400FZG-8FZG-15FZG-20FZG-30FZG-45
Internal Chamber Dimensions (mm)Φ600×976Φ1000×1527Φ1400×20541140×890×14001500×1220×14001500×1800×14003200×1220×14003200×1220×1700
Overall Dimensions (mm)1150×810×10201740×1226×13852386×1657×18001580×1203×19242060×1513×19242060×1883×19243760×1513×19243760×1513×2224
Shelf Layers468888812
Layer Spacing (mm)8198102122122122122102
Tray Dimensions (mm)310×600×45640×460×45640×460×45640×460×45640×460×45640×460×45640×460×45640×460×45
Number of Trays412321632486496
Capacity (kg)53060–8030–4060–80100–120130–150200–240
Allowable Heating-Pipe Pressure (MPa)≤0.784≤0.784≤0.784≤0.784≤0.784≤0.784≤0.784≤0.784
Operating Temperature (°C)35–15035–15035–15035–15035–15035–15035–15035–150
No-Load Chamber Vacuum (MPa)−0.09 to −0.096−0.09 to −0.096−0.09 to −0.096−0.09 to −0.096−0.09 to −0.096−0.09 to −0.096−0.09 to −0.096−0.09 to −0.096
Vacuum-Pump Model and PowerSK-1.5, 3 kWSK-3, 5.5 kWSK-6, 11 kWSK-3, 5.5 kWSK-6, 11 kWSK-6, 11 kWSK-12, 18.5 kWSK-12, 18.5 kW
Weight (kg)400900140014002300280035004800
Selection ItemInformation Required
MaterialComposition, consistency and bulk density
BatchRequired loading quantity and production schedule
MoistureInitial moisture and target final moisture
TemperatureProduct temperature limit and heating utilities
VacuumProcess pressure and expected vapor load
ConstructionContact materials, seals and cleaning requirements
InstallationSpace, access and process connections

Discuss Caffeine Crystals Drying

Send QUANPIN the incoming caffeine crystals specification, sample information and the required final product condition for an equipment review.

Start Optimizing Your
Drying Process Today.

Our engineers are ready to assess your material and recommend a reliable, cost-effective drying solution.

Chat on WhatsApp