Mixing Equipment / FZH

FZH Series Square-Cone Mixer for Food and Pharmaceutical Powder Blending
Model: FZH
A square-cone mixer uses a rotating shaped vessel to redistribute powder and granule batches. Assess this powder mixer as part of the complete mixing equipment scope, with representative dry blending and granule blending trials to check uniformity and handling after discharge.
Working Principle
Rotation changes the position of the square and conical sections relative to gravity. Material moves through the changing vessel geometry, repeatedly separating and coming back together during the mixing cycle.

Key Features
- Square and conical vessel geometry changes the material path.
- Tumbling motion redistributes compatible dry solids.
- Working fill and vessel access are selected around the batch.
Suitable Materials
- Dry powders and granules that tumble freely enough to move throughout the vessel. Material flow and particle fragility should be assessed for the proposed formulation.
- Confirm the actual material properties, moisture or solvent content, temperature sensitivity and target product condition before selecting the configuration.
Applications
Consider square-cone tumbling for compatible dry ingredient batches when vessel-based redistribution suits the formulation. Check flow and discharge behaviour before connecting the mixer to upstream preparation or downstream packaging.
Discuss your application with QUANPIN through our industries page or the inquiry form below.
Technical Parameters
On smaller screens, swipe the table sideways to view all models and values.
| Item | Dimension | 300 | 500 | 1000 | 1500 | 2000 | 3000 | 4000 | 5000 | 6000 | 8000 | 10000 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Total Volume (L) | — | 300 | 500 | 1000 | 1500 | 2000 | 3000 | 4000 | 5000 | 6000 | 8000 | 10000 |
| Maximum Filling Volume (L) | — | 210 | 350 | 700 | 1050 | 1400 | 2100 | 2800 | 3500 | 4200 | 5600 | 7000 |
| Maximum Filling Weight (kg) | — | 150 | 250 | 500 | 750 | 1000 | 1500 | 1960 | 2450 | 2950 | 3950 | 4900 |
| Main-Shaft Speed (rpm) | — | 15 | 15 | 12 | 12 | 12 | 9 | 9 | 8 | 8 | 7 | 7 |
| Motor Power (kW) | — | 1.5 | 2.2 | 4 | 5.5 | 7.5 | 11 | 15 | 15 | 15 | 18.5 | 22 |
| Feed-Port Diameter (mm) | — | 380 | 380 | 400 | 400 | 400 | 400 | 400 | 450 | 450 | 480 | 480 |
| Discharge-Port Diameter (mm) | — | 200 | 200 | 200 | 200 | 200 | 200 | 200 | 250 | 250 | 250 | 250 |
| Overall Dimensions (mm) | L | 1850 | 2200 | 2800 | 2915 | 3160 | 3800 | 3770 | 4360 | 4520 | 4890 | 5230 |
| Overall Dimensions (mm) | W | 1280 | 1550 | 2000 | 2300 | 2500 | 3200 | 3190 | 5310 | 3570 | 3790 | 4050 |
| Overall Dimensions (mm) | H | 1970 | 2260 | 2850 | 2950 | 3200 | 3850 | 4030 | 4415 | 4850 | 4880 | 5230 |
| Total Weight (kg) | — | 500 | 700 | 1000 | 1500 | 2000 | 3000 | 4000 | 5000 | 6000 | 7000 | 7800 |
Confirm the selected model, material properties and required options with QUANPIN before ordering. Final installation dimensions and equipment scope are defined in the approved technical documents.
Frequently Asked Questions
What is the FZH mixer designed to do?
A square-cone mixer uses a rotating shaped vessel to redistribute powder and granule batches.
What information is needed for model selection?
Review batch mass, bulk density, working fill and mixing time together. Confirm inlet and outlet access, available rotation clearance, product-contact surfaces and how representative samples will be taken to establish the blending endpoint.
How should mixing performance be evaluated?
Agree the formulation, batch size, sampling procedure and acceptable variation before a trial. Evaluate the discharged blend as well as the material in the vessel, because subsequent handling can affect segregation.
Selection and Configuration
For a configuration review, send the material name, bulk density, particle-size distribution, moisture level, batch mass and required blending endpoint. Working volume, drive rating, contact materials, sealing and discharge details are confirmed for the selected configuration; no numerical model rating is implied by this overview.
Discuss Your Mixing Requirements
Tell us about your material, batch size, cleaning requirements and production layout.
Application Review: Food and Pharmaceutical Powder Blending
Define the ingredients, particle-size distribution, working fill and sampling method for the proposed blend. Check uniformity after discharge as well as within the vessel.
For pharmaceutical process evaluation, consult FDA process validation guidance.
For pharmaceutical cleaning requirements, consult the FDA equipment and cleaning questions.
For food ingredients, review the Codex food hygiene and HACCP framework when defining hygienic handling.
Review the actual powder characteristics using the HSE safe handling of combustible dusts.
Include moving-part access in the installation review using HSE work equipment and guarding guidance.
Discuss Your
Mixing Process Today.
Share your formulation, batch size and blending target with our engineers to discuss a suitable mixing configuration.